Builder’s Choice Collection

 [Wood Grain | DRY BACK LVP | 2.5MM]

LIMITED WARRANTY

Finish: Limited Lifetime
Structural: 10 year Commercial

SERIES INFORMATION:

#1520 WG-DRY-#1524 WG-DRY, #1526 WG-DRY, #1530 WG-DRY

Thickness2.5MM
Width7”
Length48"
Wear Layer20MIL
SF/BOX37.65
BX/PLT40
SF/PLT1506
BX/WGT37
SF/WGT1.02 lbs
Waste %4-6%

INSTALLATION:

  • Nail
  • Nail/Glue Assist
  • Glue Only

      

  • Float
  • Click
  • Below Grade
  • Radiant Heat

ADDITIONAL INFORMATION:

Core ConstructionTuffcore LVP (Polyvinyl Chloride)
Core TypeVinyl
TextureWood Grain
Edge Profile1.0mm 45 degree angle bevel
Finish TypeCommercial Ceramic Bead Finish
Gloss Levels5 - 7%
MaintenanceZEP Neutral Floor Cleaner
Repair FinishDr. Schutz Scratch Fix - Vinyl
Design Floor Repair
Expansion Requirements1/4” expansion gap for the first 20 Lineal feet (length or width). Add additional 1/16” for every 5’ of install (length or width) up to 1/2”. T-molds are required for rooms exceeding 50 lineal feet in length and width and 40 lineal feet for installations over in floor radiant heat.
UsesResidential - Commercial

COMPLIANCE:

This series has been tested and contains the following certifications:

COMMON QUESTIONS:

SUBSTRATE REQUIREMENTS
 Structurally sound, well bounded, flat to within 3/16” in 10’ radius or 1/8” in 6’ radius, vertical deflection cannot exceed 1/4” in 10’ Radius, or more than 1/16” between the floor joist.

APPROVED SUBSTRATES
Concrete subfloor, Wood subfloor suspended at least 18” above the ground, Existing floor coverings provided the existing floor surface is smooth, or can be made smooth.

WOOD SUBFLOOR (EMC) MOISTURE CONTENT REQUIREMENTS
Wood subfloors must be suspended a minimum for 18” from the ground with adequate ventilation. The ground surface of the crawl space must be covered with a vapor barrier. Should not exceed12% MC (moisture content).

CONCRETE AND GYPCRETE MOISTURE EMISSIONS, RH, AND PH REQUIREMENTS

JOBSITE CONDITION RANGES
RH between 30-60% and room temperature between 60 to 80°F. Post installation temperature range must be within 10 to 142°F

ACCLIMATION TIMEFRAME
No acclimation is required if the product was stored and/or transported in 60 to 80°F for at least 48 hours prior to installation. Otherwise, it must acclimate for a minimum of 24 hours. Please see installation guide for radiant heat application.

CAN WE INSTALL A CUSHION UNDERNEATH THE FLOOR?
 No. This product was developed to be installed directly onto an approved substrate.

RUG COMPATIBILITY
 Must be breathable, non abrasive, natural fiber rugs. Please see RugPadUSA.com. For example; Anchor Grip, Nature’s Grip, RugPro, or Super Lock Natural.

BUILDER’S CHOICE COLLECTION DRYBACK LVP: