Montana Collection
[Hand Scraped | Engineered | 1/2”]
LIMITED WARRANTY
Finish: 25 year
Structural: Lifetime
SERIES INFORMATION:
#303 HS-E – #309 HS-E
Species/Janka | Hickory (1780) |
Thickness | 1/2” |
Width | 6 1/2” |
Length | 1.5’-6’ |
Wear Layer | 2MM |
SF/BOX | 25.73 |
BX/PLT | 36 |
SF/PLT | 926 |
BX/WGT | 47 |
SF/WGT | 1.83 lbs. |
Waste % | 4-6% |
INSTALLATION:
ADDITIONAL INFORMATION:
Core Construction | 7 Ply - Hardwood |
Core Type | Plywood |
Joint System | Tongue and Groove |
Texture | Hand Scraped (Hand Crafted)/Brushed |
Edge Profile | Hand Sculpted, Chattered, Pillowed Edge |
Finish Type | 9 Finish Coats - UV cured urethane infused with aluminum oxide |
Gloss Levels | 13%-16% |
Maintenance | Bona Hardwood Formula |
Repair Finish | Can be screened and recoated with Bona HD Traffic (or similar) |
Expansion Requirements | Requires 1/2” expansion gap. Floating installations require T-molds for installations exceeding 40 lineal feet in length or width and 30 lineal feet for installations over in floor radiant heat. |
Fastener Requirements | 18 gauge, L/T cleats or 1/4” crown staples, minimum 1-1/2” long. Fasteners spacing 1-1/2” from the board ends and every 3”- 4” along the tongue |
Uses | Residential Light Duty Commercial |
COMPLIANCE:
COMMON QUESTIONS:
SUBSTRATE REQUIREMENTS
Structurally sound, well bounded, flat to within 3/16” in 10’ radius, or 1/8” in 6’ radius. Vertical deflection cannot exceed 1/4” in 10’ radius, or more than 1/16” between the floor joist.
APPROVED SUBSTRATES
Underlayment APA grade CDX plywood/OSB, 3000 PSI concrete or 2500 PSI gypcrete. Underlayment grade MDF (floating only).
WOOD SUBFLOOR (EMC) MOISTURE CONTENT REQUIREMENTS
Engineered wood MC (moisture content) must test within 3% of the wood subfloor. Neither can exceed 12%. If the MC falls outside this range, a longer acclimation period is required to reach equilibrium.
CONCRETE AND GYPCRETE MOISTURE EMISSIONS, RH, AND PH REQUIREMENTS
Installing a vapor barrier is not required, but it is strongly
recommended on installations over on or above grade slabs with a calcium chloride reading under 3 lbs /1000sf per 24 hours or under 75% relative humidity as determined by current ASTM standards, or a CM (calcium carbide) rating of 2.5% or less. The pH levels must be between 5 – 9. Below grade and any substrate over 3 lbs /1000sf per 24 hours require a vapor barrier.
JOBSITE CONDITION RANGES
Prior, during, and after installation, the jobsite RH must be maintained between 35-55%, and the room temperature between 60-80°F.
ACCLIMATION TIMEFRAME
Minimum 24 hours to reach room temperature between 60-80°F and 48 hours if the material was stored or transported in temperature below 60°F within 24 hours of install.
CAN WE INSTALL A CUSHION UNDERNEATH THE FLOOR?
YES, FOR FLOATING INSTALLATION ONLY. Approved cushions are high density #59EVA 3mm, #59IXPE 3mm, #60PVC 1.5mm, and cork up to 1/4” in thickness. EPE economical cushion is not recommended.
RUG COMPATIBILITY
Must be breathable, non abrasive, natural fiber rugs. Please see RugPadUSA.com. For example; Eco Plush 3/8”, Contour Lock, RugPro, or Superior Lock 1/4”.RugPro, or Superior Lock 1/4”.