Market and Main Collection

[Hand Scraped, Registered Embossed | WPC | 7.5MM]

LIMITED WARRANTY

Finish: Limited Lifetime
Structural: 10 year Commercial

SERIES INFORMATION:

#1350-#1354, #1365-#1366

Thickness7.5MM
Width7 1/8”
Length60"
Wear Layer20MIL
SF/BOX17.35
BX/PLT75
SF/PLT1301
BX/WGT30
SF/WGT1.73 lbs
Waste %5-8%

#1360-#1364

Thickness7.5MM
Width7 1/8”
Length60"
Wear Layer20MIL
SF/BOX19.56
BX/PLT75
SF/PLT1467
BX/WGT32
SF/WGT1.64 lbs
Waste %5-8%

INSTALLATION:

  • Nail
  • Nail/Glue Assist
  • Glue Only
  • Float
  • Click
  • Below Grade
  • Radiant Heat

ADDITIONAL INFORMATION:

Core ConstructionTuffcore WPC (Polyvinyl Chloride)
Core TypePVC (Virgin) 970+ PSI
Joint SystemValinge 2g Click - Angle / Angle
TextureReg. Embossed or Hand Scraped
(Depending on color)
Edge ProfileEnhanced Bevel 1mm
Finish Type2 Coats of UV cured urethane with hardener
Gloss Levels5 - 7%
MaintenanceZEP Neutral Floor Cleaner
Repair FinishDr. Schutz Scratch Fix - Vinyl Design Floor Repair
Impact Sound ReductionICC Rating 62dB
Sound Transmission ReductionSTC Rating 61dB
Expansion Requirements1/4” expansion gap for the first 20 Lineal feet (length or width). Add additional 1/16” for every 5’ of install (length or width) upto 5/8”. T-molds are required for rooms exceeding 40 lineal feet in length and width and 35 lineal feet for installations over in floor radiant heat.
UsesResidential - Commercial

COMPLIANCE:

This series has been tested and contains the following certifications:

COMMON QUESTIONS:

SUBSTRATE REQUIREMENTS
Structurally sound, well bounded, flat to within 3/16” in 10’ radius or 1/8” in 6’ radius, vertical deflection cannot exceed 1/4” in 10’ Radius, or more than 1/16” between the floor joist.

APPROVED SUBSTRATES
Underlayment APA grade CDX plywood/OSB, 3000 PSI concrete or 2500 PSI gypcrete. Underlayment grade MDF. See installation guide for additional approved substrates.

WOOD SUBFLOOR (EMC) MOISTURE CONTENT REQUIREMENTS
Should not exceed 12% MC (moisture content).

CONCRETE AND GYPCRETE MOISTURE EMISSIONS, RH, AND PH REQUIREMENTS
Properly install a minimum of 6mil plastic over the entire sub-strate. Overlap all seams 12” and tape all seams with moisture proof tape.

JOBSITE CONDITION RANGES
RH between 30-60% and room temperature between 60 to 80°F. Post installation temperature range must be within 60 to 142°F.

ACCLIMATION TIMEFRAME
No acclimation is required if the product was stored and/or transported in 60 to 80°F for at least 24 hours prior to installation. Otherwise, it must acclimate for a minimum of 24 hours. Please see installation guide for radiant heat application.

CAN WE INSTALL A CUSHION UNDERNEATH THE FLOOR?
This product has an attached 1mm thick high density cork underlayment. An additional cushion is not needed. However, only the NFP #60PVC high density cushion can be installed underneath.

RUG COMPATIBILITY
Must be breathable, non abrasive, natural fiber rugs. Please see RugPadUSA.com. For example; Anchor Grip, Nature’s Grip, RugPro, or Super Lock Natural.