Michigan Collection

[Smooth | Solid | 3/4”]

LIMITED WARRANTY

Finish: 25 year
Structural: Lifetime

SERIES INFORMATION:

#259 SM-S, #260 SM-S, #261 SM-S, #263 SM-S, #264 SM-S

Core ConstructionSolid Wood
Joint SystemTongue and Groove
TextureReg. Embossed or Hand Scraped
(Depending on color)
Edge ProfileMicro Beveled
TextureSmooth
Finish Type9 Finish Coats - UV cured urethane infused with aluminum oxide
Gloss Levels19% -21%
MaintenanceBona Hardwood Formula
Repair FinishCan be screened and recoated with Bona HD Traffic (or similar)
Expansion RequirementsRequires minimum of 1/2” expansion
gap around all fixed objects and walls
Fastener
Requirements
15-16 gauge, L/T cleats, or 7/16” to 1/2” crown staples, minimum 1 3/4” Length. Fastener spacing 1 1/2” from the board ends and every 6” - 8” along the tongue.
UsesResidential Light Duty
Commercial

INSTALLATION:

  • Nail
  • Nail/Glue Assist
  • Glue Only

    (with limitations)

  • Float
  • Click
  • Below Grade
  • Radiant Heat

ADDITIONAL INFORMATION:

Core ConstructionSolid Wood
Joint SystemTongue and Groove
TextureReg. Embossed or Hand Scraped
(Depending on color)
Edge ProfileMicro Beveled
TextureSmooth
Finish Type9 Finish Coats - UV cured urethane infused with aluminum oxide
Gloss Levels19% -21%
MaintenanceBona Hardwood Formula
Repair FinishCan be screened and recoated with Bona HD Traffic (or similar)
Expansion RequirementsRequires minimum of 1/2” expansion
gap around all fixed objects and walls
Fastener
Requirements
15-16 gauge, L/T cleats, or 7/16” to 1/2” crown staples, minimum 1 3/4” Length. Fastener spacing 1 1/2” from the board ends and every 6” - 8” along the tongue.
UsesResidential Light Duty
Commercial

COMPLIANCE:

This series has been tested and contains the following certifications:

COMMON QUESTIONS:

SUBSTRATE REQUIREMENTS
Structurally sound, well bounded, flat to within 3/16” in 10’ radius, or 1/8” in 6’ radius. Vertical deflection cannot exceed 1/4” in 10’ radius, or more than 1/16” between the floor joist.

APPROVED SUBSTRATES
Underlayment APA grade CDX plywood/OSB. See NWFA guidelines for 3000 PSI concrete or 2500 PSI gypcrete.

WOOD SUBFLOOR (EMC) MOISTURE CONTENT REQUIREMENTS
Solid wood MC (moisture content) must test within 2% of the wood subfloor. Neither can exceed 12%.

CONCRETE AND GYPCRETE MOISTURE EMISSIONS, RH, AND PH REQUIREMENTS
Random width and/or narrower than 4 1/4” ONLY. Check with NWFA for an approved adhesive and/or moisture mitigation system for concrete/gypcrete, RH, pH, and installation requirements. (Bond and moisture mitigation warranties comes soley from glue and/or vapor barrier manufacturer.)

JOBSITE CONDITION RANGES
Prior, during, and after installation, the jobsite RH must be maintained between 35-55%, and the room temperature between 60-80°F.

ACCLIMATION TIMEFRAME
Minimum 72 hours to reach room temperature between 60-80 °F. The subfloor and the wood flooring MC (moisture content) must test within 2% of each other and does exceed 12%. If the MC falls outside this range, a longer acclimation period is required to reach equilibrium.

CAN WE INSTALL A CUSHION UNDERNEATH THE FLOOR?
Cushion is not compatible.

RUG COMPATIBILITY
Must be breathable, non abrasive, natural fiber rugs. Please see RugPadUSA.com. For example; Eco Plush 3/8”, Contour Lock, RugPro, or Superior Lock 1/4”.

MICHIGAN COLLECTION SOLID HARDWOOD FLOORING: