Montana Collection

[Circle/Band Sawn | Engineered | 1/2”]

LIMITED WARRANTY

Finish: 25 year
Structural: Lifetime

SERIES INFORMATION:

#340 CS-E-#345 CS-E

Species/JankaHickory (1780)
Thickness1/2”
Width4”/5”/6”
Length1.5’-6’
Wear Layer2MM
SF/BOX29.53
BX/PLT32
SF/PLT945
BX/WGT49
SF/WGT1.66 lbs.
Waste %4-6%

INSTALLATION:

  • Nail
  • Nail/Glue Assist
  • Glue Only
  • Float
  • Below Grade
  • Radiant Heat

    (with limitations)

  • Click

ADDITIONAL INFORMATION:

Core Construction7 Ply - Hardwood
Core TypePlywood
Joint SystemTongue and Groove
TextureCircle/Band Sawn
Edge ProfileHand Sculpted, Chattered, Pillowed Edge
Finish Type9 Finish Coats - UV cured urethane infused with aluminum oxide
Gloss Levels13%-16%
MaintenanceBona Hardwood Formula
Repair FinishCan be screened and recoated with Bona HD Traffic (or similar)
Expansion RequirementsRequires 1/2” expansion gap. Floating installations require T-molds for installations exceeding 40 lineal feet in length or width and 30 lineal feet for installations over in floor radiant heat.
Fastener
Requirements
18 gauge, L/T cleats or 1/4” crown staples, minimum 1-1/2” long. Fasteners spacing 1-1/2” from the board ends and every 3”- 4” along the tongue
UsesResidential
Light Duty Commercial

COMPLIANCE:

This series has been tested and contains the following certifications:

COMMON QUESTIONS:

SUBSTRATE REQUIREMENTS
Structurally sound, well bounded, flat to within 3/16” in 10’ radius, or 1/8” in 6’ radius. Vertical deflection cannot exceed 1/4” in 10’ radius, or more than 1/16” between the floor joist.

APPROVED SUBSTRATES
Underlayment APA grade CDX plywood/OSB, 3000 PSI concrete or 2500 PSI gypcrete. Underlayment grade MDF (floating only).

WOOD SUBFLOOR (EMC) MOISTURE CONTENT REQUIREMENTS
Engineered wood MC (moisture content) must test within 3% of the wood subfloor. Neither can exceed 12%. If the MC falls outside this range, a longer acclimation period is required to reach equilibrium.

CONCRETE AND GYPCRETE MOISTURE EMISSIONS, RH, AND PH REQUIREMENTS
Installing a vapor barrier is not required, but it is strongly recommended on installations over on or above grade slabs with a calcium chloride reading under 3 lbs /1000sf per 24 hours or under 75% relative humidity as determined by current ASTM standards, or a CM (calcium carbide) rating of 2.5% or less. The pH levels must be between 5 – 9. Below grade and any substrate over 3 lbs /1000sf per 24 hours require a vapor barrier.

JOBSITE CONDITION RANGES
Prior, during, and after installation, the jobsite RH must be maintained between 35-55%, and the room temperature between 60-80°F.

ACCLIMATION TIME FRAME
Minimum 24 hours to reach room temperature between
60-80°F and 48 hours if the material was stored or transported in temperature below 60°F within 24 hours of install.

CAN WE INSTALL A CUSHION UNDERNEATH THE FLOOR?
YES, FOR FLOATING INSTALLATION ONLY. Approved cushions are high density #59EVA 3mm, #59IXPE 3mm, #60PVC 1.5mm, and cork up to 1/4” in thickness. EPE economical cushion is not recommended.

RUG COMPATIBILITY
Must be breathable, non abrasive, natural fiber rugs. Please see RugPadUSA.com. For example; Eco Plush 3/8”, Contour Lock, RugPro, or Superior Lock 1/4”.RugPro, or Superior Lock 1/4”.

MONTANA COLLECTION ENGINEERED HARDWOOD FLOORING: